FL SWITCH MM HS
4-106
PHOENIX CONTACT 6874_en_09
Description Displays the port number.
flWorkFWCtrlProfinetAlarmPortLinkMonitoring
OID 1.3.6.1.4.1.4346.11.11.11.2.9.1.1.1.2
Syntax Integer
Access Read and write
Description In PROFINET mode, a slot can send an alarm if the link status changes from "Connected"
to "Not connected":
Do not send alarm 1
Send alarm 2
flWorkFWCtrlProfinetAlarmPortPofScrjDiag
OID 1.3.6.1.4.1.4346.11.11.11.2.9.1.1.1.3
Syntax Integer
Access Read and write
Description In PROFINET mode, a slot can send an alarm if the transmission power of a POF-SCRJ
port reaches a critical value or the port enters a critical state:
Do not send alarm 1
Send alarm 2
flWorkFWCtrlProfinetAlarmPowerSupply
OID 1.3.6.1.4.1.4346.11.11.11.2.9.1.1.1.10
Syntax Integer
Access Read and write
Description In PROFINET mode, the switch can send an alarm if one of the redundant power supplies
fails:
Do not send alarm 1
Send alarm 2
flWorkFWCtrlProfinetAlarmModuleRemove
OID 1.3.6.1.4.1.4346.11.11.11.2.9.1.1.1.11
Syntax Integer
Access Read and write
Description In PROFINET mode, the switch can send an alarm if one of the interface modules is
removed:
Do not send alarm 1
Send alarm 2
Przeglądanie stron 177